Product features
- 1 Cable entry M 20 x 1.5
- IDC method of termination
- Manual release
- Thermoplastic enclosure
- Double-insulated
- Compact design
- Interlock with protection against incorrect locking.
- Long life
- High holding force
General data
- Standards: EN ISO 13849-1, EN ISO 14119, EN IEC 60947-5-1
- Coding level according to EN ISO 14119: Low
- Working principle: electromechanical
- Housing material: Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
- Gross weight: 272 g
General data - Features
- Power to unlock: Yes
- Number of actuating directions: 2
- Number of safety contacts: 2
Safety classification
- Standards: EN ISO 13849-1
- Performance Level, up to: c
- Category: 1
- B10D Normally-closed contact (NC): 2,000,000 Operations
- Note: Electrical life on request.
- B10D Normally-open contact (NO): 1,000,000 Operations
- Note: at 10% Ie and ohmic load
- Mission time: 20 Year(s)