Product features
3 cable entries M 16 x 1.5
Thermoplastic enclosure
Individual coding
Coding level "High" according to ISO 14119
52 mm x 90 mm x 30 mm
Long life
Double-insulated
Large wiring compartment
High level of contact reliability with low voltages and currents
Insensitive to soiling
Slotted holes for adjustment, circular holes for location
General data
Standards: EN ISO 13849-1, EN ISO 14119, EN IEC 60947-5-1
Coding level according to EN ISO 14119: High
Housing material: Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
Material of the actuator: Stainless steel
Gross weight: 193g
General data - Features
Ejection force: Yes
Number of auxiliary contacts: 1
Number of safety contacts: 2
Safety classification
Standards: EN ISO 13849-1
Performance Level, up to: c
Category: 1
B10D Normally-closed contact (NC): 2,000,000 Operations (Note: Electrical life on request)
B10D Normally-open contact (NO): 1,000,000 Operations (Note: at 10% Ie and ohmic load)
Mission time: 20 Years