Product features
- 3 cable entries M 16 x 1.5
- Large wiring compartment
- Integrated status indicator
- Thermoplastic enclosure
- Double-insulated
- 52 mm x 90 mm x 30 mm
- Universal coding
- Long life
- High level of contact reliability with low voltages and currents
- Insensitive to soiling
- Slotted holes for adjustment, circular holes for location
General data
- Standards: EN ISO 13849-1, EN ISO 14119, EN IEC 60947-5-1
- Coding level according to EN ISO 14119: Low
- Working principle: Electromechanical
- Housing material: Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
- Gross weight: 120 g
General data - Features
- Ejection force: Yes
- Indicator lamp: Yes
- Integral system diagnostics, general: Yes
- Number of actuating directions: 3
- Number of auxiliary contacts: 1
- Number of safety contacts: 2
- Number of cable glands: 3
Safety Classification
- Standards: EN ISO 13849-1
- Performance Level, up to: c
- Category: 1
- B10D Normally-closed contact (NC): 2,000,000 Operations (Note: Electrical life on request)
- B10D Normally-open contact (NO): 1,000,000 Operations (Note: at 10% Ie and ohmic load)
- Mission time: 20 Years