General data
-Standards:
BG-GS-ET-14
BG-GS-ET-20
EN IEC 62061
EN ISO 13849-1
EN IEC 60947-5-1
EN IEC 60947-5-3
EN IEC 60947-5-5
EN IEC 60204-1
EN IEC 60947-1
Climatic stress
-EN 60068-2-3
-BG-GS-ET-14
Housing material
-Glass-fibre reinforced thermoplastic, ventilated
Gross weight
-164 g
General data - Features
-Wire breakage detection
-Automatic reset function
-Reset after disconnection of supply voltage
-Integral system diagnostics, status
-Number of LEDs: 1
-Number of normally closed (NC): 4
-Number of normally open (NO): 2
-Number of safety contacts: 1
Safety classification
Standards:
-EN ISO 13849-1
-EN IEC 61508
Safety classification - Relay outputs
-Performance Level, up to: c
-Category: 1
-PFH value: 1.14 x 10⁻⁶ /h
-Notice: for max. 50,000 switching cycles/year and max. 80% contact load
-Safety Integrity Level (SIL), suitable for applications in: 1
-Mission time: 20 Year(s)
Mechanical data
-Mechanical life, minimum: 3,000,000 Operations
-Mounting: Snaps onto standard DIN rail to EN 60715
Mechanical data - Connection technique
-Terminal designations: IEC/EN 60947-1
-Termination:
-Rigid or flexible
-Screw terminals M20 x 1.5
-Cable section, maximum: 2.5 mm²
-Tightening torque of Clips: 0.6 Nm
Mechanical data - Dimensions
-Width: 22.5 mm
-Height: 75 mm
-Depth: 110 mm
Ambient conditions
-Degree of protection of the enclosure: IP40
-Degree of protection of the mounting space: IP54
-Degree of protection of clips or terminals: IP20
-Ambient temperature: +0 ... +55 °C
-Storage and transport temperature: -25 ... +70 °C
-Resistance to vibrations: 10...55 Hz, Amplitude 0.35 mm, ± 15 %
-Restistance to shock: 30 g / 11 ms
Ambient conditions - Insulation values
-Rated impulse withstand voltage Uimp: 4 kV
-Overvoltage category: III
-Degree of pollution: 2
Electrical data
-Frequency range: 50 Hz, 60 Hz
-Thermal test current: 4A
-Rated operating voltage: 110 VAC
-Rated AC voltage for controls, 50 Hz, minimum: 93.5 VAC
-Rated control voltage at AC 50 Hz, maximum: 121 VAC
-Rated AC voltage for controls, 60 Hz, minimum: 93.5 VAC
-Rated control voltage at AC 60 Hz, maximum: 121 VAC
-Electrical power consumption: 2.4 W
-Contact resistance, maximum: 0.1 Ω
-Note (Contact resistance): in new state
-Drop-out delay in case of power failure, typically: 80 ms
-Drop-out delay in case of emergency, typically: 20 ms
-Pull-in delay at automatic start, maximum, typically: 100 ms
-Pull-in delay at RESET, typically: 20 ms
-Material of the contacts, electrical: AgCdO
Electrical data - Safe relay outputs
-Voltage, Utilisation category AC-15: 250 VAC
-Current, Utilisation category AC-15: 1.5 A
-Voltage, Utilisation category DC-13: 24 VDC
-Current, Utilisation category DC-13: 1A
-Switching capacity, minimum: 10 VDC
-Switching capacity, minimum: 10 mA
-Switching capacity, maximum: 250 VAC
-Switching capacity, maximum: 8A
Electrical data - Digital inputs
-Conduction resistance, maximum: 40 Ω
Electrical data - Digital Output
-Voltage, Utilisation category DC-12: 24 VDC
-Current, Utilisation category DC-12: 0.1 A
Electrical data - Relay outputs (auxiliary contacts)
-Switching capacity, maximum: 24 VDC
-Switching capacity, maximum: 2A
-Electrical data - Electromagnetic compatibility (EMC):
-EMC rating: EMC-Directive
Status indication
-Indicated operating states: Authorised operation
Other data
-Note (applications): Safety sensor, Guard system