Product features
- Large wiring compartment
- Emergency exit, cover-side
- Emergency exit, rear
- cable entries 4 M 16 x 1.5
- Thermoplastic enclosure
- Double-insulated
- Interlock with protection against incorrect locking.
- 130 mm x 90 mm x 30 mm
- 6 Contacts
- Long life
General data
- Standards: EN ISO 13849-1, EN ISO 14119, EN IEC 60947-5-1
- Coding level according to EN ISO 14119: Low
- Working principle: Electromechanical
- Housing material: Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
General data - Features
- Power to unlock: Yes
- Emergency exit: Yes
- Manual release: Yes
- Number of actuating directions: 3
- Number of auxiliary contacts: 2
- Number of safety contacts: 4
Safety Classification
- Standards: EN ISO 13849-1
- Performance Level, up to: c
- Category: 1
- B10D Normally-closed contact (NC): 2,000,000 operations (Note: Electrical life on request)
- B10D Normally-open contact (NO): 1,000,000 operations (Note: at 10% Ie and ohmic load)
- Mission time: 20 years