Product Overview:
-LS Manual Motor Starters (MMS) is a high-performance and reliable motor protection product.
-It combines the functions of MCCB (Molded Case Circuit Breaker) and TOR (Thermal Overload Relay).-Applications of the product:
+Protecting groups of interconnected circuits.
+Protecting individual electrical circuits.
+Protecting motors.
+Protecting electrical starting devices.
-The product can:
+Prevent overloads.
+Prevent phase loss.
+Prevent short circuits.
+Automatically adjust and compensate for temperature.
+Adjust current.
-Features of the product:
+Handle lock in the OFF position.
+Safe electrical connections to prevent contact with hazardous elements.
+Can be mounted on DIN rail or with screws.
+Trip indication (to check if the product is functioning).
+Class 10 overload protection characteristics.
+Can be connected with various accessories provided by the manufacturer to add functionality.
+Ready for IE3.
-The product complies with standards:
+IEC 60947-2 and IEC 60947-4-1.
+UL508.
+CSA C22.2 NO.14.
+GB14048.
-Certifications:
+CE.
+CCC.
+UL.
+EAC.
+Marine.
+KC.
Technical specifications:
Rated operational voltage (Ue) | Up to 690V |
Rated frequency | 50/60 Hz |
Rated insulation voltage (Ui) | 690V |
Rated impulse voltage (Uimp) | 6kV |
Utilization category according to IEC 60 947-2 (Breaker) | Cat.A |
Utilization category according to IEC 60 947-4 (Motor starter) | AC 3 |
Mechanical endurance (Cycles) | 100k |
Electrical endurance (Cycles) | 100k |
Max operating frequency per hour (Ope./h) | 25 |
Temperature compensation (Operation) | -20 to 60°C |
Instantaneous short circuit release | 13 X Ie(max) |
Overload protection | Yes |
Phase failure function | Yes |
Trip indicating function | No |
Test function | Yes |
Weight (g) | 320 |
Number of poles | 3 |
Rated breaking capacity (kA) | Rated operational current (Ie), unit : A | Thermal release adjustment range (Ie), unit : A | 240V 230V 220V | 415V 400V | 460V 440V | 525V 500V | 690V 600V |
Icu | Ics | Icu | Ics | Icu | Ics | Icu | Ics | Icu | Ics |
10 | 6-10 | 100 | 100 | 50 | 38 | 15 | 11 | 6 | 5 | 3 | 3 |
Rated operational current (A) | Magnetic release operating current (A) | Switching of 3 phase AC motors, AC-2, AC-3 |
3-phase [kW] (50/60Hz) | 3-phase [HP] (60Hz) |
230V | 400V | 690V | 230V | 460V | 575V |
10 | 130 | 3 | 4 | 7.5 | 3 | 7½ | 10 |
Product dimensions (mm):
Product:
Note:
+For your safety, please read the instructions carefully before use.
+Perform regular maintenance on the product.
+All routine maintenance or inspections should be performed by qualified personnel.
+Contact the nearest authorized service facility for inspection, repair, or adjustment.
+Inspect the product before use.