Sensing type
|
Through-beam type
|
Light source
|
Infrared LED(855nm)
|
Effective aperture angle(EAA)
|
Within ± 2.5 ° when the sensing distance is greater than 3 m for both emitter and receiver.
|
Sensing distance
|
Short - Long mode (setting switch)
|
Short mode
|
0,2 to 5 m
|
Long mode
|
0,2 to 10 m
|
Detection capability
|
Ø 14 mm (finger)
|
Sensing target
|
Opaque
|
Number of optical axes
|
103
|
Optical axis pitch
|
9mm
|
Series connection
|
Max. 3 SET (≤ 300 optical axes)
|
Power supply
|
24 VDC ±20 %(ripple P-P: ≤10 %)
|
Current consumption
|
Emitter: ≤106mA, receiver: ≤181mA
|
Safety related output: OSSD output
|
NPN or PNP open collector Load voltage : ON - 24 VDC (except for the residual voltage)
|
Auxiliary output(AUX 1/2)
|
"NPN or PNP open collector
Load voltage: ≤ 24 VDC
|
Lamp output(LAMP 1/2)
|
NPN or PNP open collector
Load voltage: ≤ 24 VDC, Load current: ≤ 300 mA
|
Protection circuit
|
Reverse power polarity, reverse output polarity, output short-circuit over-current protection
|
Safety-related functions
|
Interlock (reset hold), external device monitoring (EDM), muting/override, Blanking (fixed blanking, floating blanking), reduced resolution
|
General functions
|
Self-test, alarm for reduction of incident light level, mutual interference prevention
|
Others functions
|
Change of sensing distance, switching to NPN or PNP, external test (light emission stops), auxiliary output (AUX 1, 2), lamp output (LAMP1, 2)
|
Synchronization type
|
Timing method by synchronous line
|
Insulation resistance
|
Over 20MΩ (at 500VDC megger)
|
Noise immunity
|
The square wave noise (pulse width: 1㎲) by the noise simulator ±240VDC
|
Dielectric strength
|
1,000VAC 50/60Hz for 1 minute
|
Vibration
|
0.7 mm double amplitude at frequency of 10 to 55Hz, 20 sweeps ni each X, Y, Z direction
|
Shock
|
100 m/s² ( 10 G), pulse width 16 ms in each X, Y, Z direction for 1,000 times
|
Environment_Ambient illumination
|
Sunlight: Max. 10,000lx, Incandescent lamp: Max. 3,000lx (received illumination)
|
Ambient temperature
|
-10 to 55℃, storage: -20 to 70℃ (non-freezing or non-condensation)
|
Ambient humidity
|
35 to 85 %RH, storage: 35 to 95 %RH (non-freezing or non-condensation)
|
Protection structure
|
IP65, IP67(IEC Standard), IP67G (JEM Standard), IP69K (DIN Standard)
|
Material
|
Case: Aluminum, Front cover and sensing part: Polymethyl methacrylate, End cap: polycarbonate, Power I/O cable and connector cable: polyurethane (PUR) or polyvinyl chloride (PVC), Y type connector cable: polyvinyl chloride (PVC), lamp output cable and series connector cable: polyurethane (PUR), Top / Bottom adjustable bracket and Top / Bottom bracket: SUS304, Side adjustable bracket and Side bracket: nickel plated Zn
|
International standards
|
UL 508, CSA C22.2 No. 14, ISO 13849-1 (PL e, Cat. 4), ISO 13849-2 (PLe, Cat. 4), UL 61496-1 (Type 4, ESPE), UL 61496-2 (Type 4, AOPDs), IEC/EN 61496-1 (Type 4, ESPE), IEC/EN 61496-2 (Type 4, AOPDs), IEC/EN 61508-1~-7 (SIL 3), IEC/EN 62061 (SIL CL 3)
|