Product features
-Thermoplastic enclosure
-Eight approach levels thanks to rotating head
-Individually coded version with coding level "High" according to ISO 14119
-Simple fitting, especially on 40 mm profiles
General data
-Standards: EN ISO 13849-1/ EN ISO 14119/ EN IEC 60947-5-1
-Coding level according to EN ISO 14119: High
-Working principle: electromechanical
-Housing material: Thermoplastic, Polyamide PA 6 GF
-Gross weight: 622 g
General data - Features
-Power to unlock: Yes
-Manual release: Yes
-Number of actuating directions: 2
-Number of safety contacts: 4
Mechanical data - Connection technique
-Cable entry: 3 x M20 x 1,5
-Termination: Screw terminals
-Cable section, minimum: 0.25 mm²
-Cable section, maximum: 2.5 mm²
-Note: All indications including the conductor ferrules.
-Allowed type of cable: Solid single-wire/ Solid multi-wire/ Flexible
Mechanical data
-Mechanical life, minimum: 1,000,000 Operations
-Note (Mechanical life): from device version V2 (see type plate)
-Holding force FZh in accordance with EN ISO 14119: 1,500 N
-Holding force Fmax, maximum: 1,950 N
-Latching force, approx.: 50 N
-Positive break travel: 10 mm
-Positive break force per NC contact, minimum: 10 N
-Positive break force, minimum: 40 N
-Actuating speed, maximum: 0.3 m/s
-Mounting: Screws
-Type of the fixing screws: 4x M5
-Tightening torque of the fastening screws for the housing cover: 0.5 Nm
-Note: Torx T10
Mechanical data - Dimensions
-Length of sensor: 48 mm
-Width of sensor: 40 mm
-Height of sensor: 204 mm