Timer Hanyoung: T57N-E-30-B

Order code:

Model

Code

Description

 

 

 

 

 

Model

 

 

 

 

Analog Timer

 

T38N

 

 

 

48.0(W)      59.0(H)

It’s necessary to use Panel Mount Adaptor in Case of Panel Type

T48N

 

 

 

48.0(W)      48.0(H)

T57N

 

 

 

 

 

E Size - 50.0(W)       62.0(H)

P Size - 57.5(W)       84.5(H)

TF62N

 

 

 

 

TF62D

 

 

 

Fixture type

E

 

 

Exposure type

P

 

 

Panel type

 

 

 

Time Range

01

 

1 sec / 1 min / 1 hour

03

 

3 sec / 3 min / 3 hour

06

 

6 sec / 6 min / 6 hour

10

 

10 sec / 10 min / 10 hour

30

 

30 sec / 30 min / 30 hour

60

 

60 sec / 60 min / 60 hour

12H

 

12 hour / 24 hour / 48 hour (exception : TF62N & TF62D)

 

 

Control output

A

Time - limit 1c + Constant 1a (For T38N / T48N / T57N)

B

Time - limit 1c + Constant 1c (For T38N / T48N / T57N)

C

Time - limit 2c (For T38N / T48N / T57N)

D

Time - limit 1c (For TF62N)

F

Time - limit 2c (For TF62D)

 

Specifications:

 

MOD

 

EL

Exposure type(E)

T38N

T48N

T57N-E

TF62N-E

TF62D-E

Panel type(P)

T57N-P

TF62N-P

TF62D-P

Function

POWER ON DELAY TIMER

TWIN TIMER

DUAL TIMER

Power supply

24 - 240 V a.c 50 - 60 , 24 - 240 V d.c

Allowable Voltage Fluctuation

% of Power supply voltage

Power Consumption

Less than 4.5 VA (at 240 V a.c 60       ), Less than 1.5 W (at 24 V d.c )

Return time

Less than 100

 

 

 

Time Range

01

0.01 ~ 1 s / 0.01 ~ 1 m / 0.01 ~ 1 h

03

0.01 ~ 3 s / 0.01 ~ 3 m / 0.01 ~ 3 h

06

0.01 ~ 6 s / 0.01 ~ 6 m / 0.01 ~ 6 h

10

0.01 ~ 10 s / 0.01 ~ 10 m / 0.01 ~ 10 h

30

0.01 ~ 30 s / 0.01 ~ 30 m / 0.01 ~ 30 h

60

0.01 ~ 60 s / 0.01 ~ 60 m / 0.01 ~ 60 h

12H

0.01 ~ 12 h / 0.01 ~ 24 h / 0.01~ 48 h ( 24h

)

 

‘12’ model is not availale

Time Error

Repeat error

Less than      0.3 % (ratio against Max. scale)

Setup error

Less than      5 % (ratio against Max. scale)

 

Contol output

Output mode

Power Time - limit

FLICKER (ON Start)

FLICKER (ON -A Start)

Contact construction

A type (Time - limit 1c + Instantaneous 1a) / B type (Time - limit 1c + Instantaneous 1c) / C type(Time - limit 2c)

D type (Time - limit 1c)

F type (Time - limit 2c)

Capacity

250 V a.c 3 A Resistive load

Life span of relay

Mechanical : More than 10 million times / Electrical : More than 100,000 times

Dielectric strength

2000 V a.c 50/60       for 1 minute

Noise

2 kV

Insulation resistance

More than 100      (Based on 500 V d.c mega standard)

Vibration (Durability)

10 - 55       (cycle :1 minute), Double amplitude 0.5       

 

for 2h.

 

 

Shock (Durability)

300      (30 G) X Y Z each direction 3 times

Ambient temperature

-10 ~ 55       Without freeze

Storage temperature

-25 ~ 65       Without freeze

Ambient humidity

30 ~ 85 % R.H.

Certification

 

cetified (Exception : TF62D)

          

Front View:

Front View:

Function                                                            

Contents                                                                          

 

T38N T48N T57N

 

Output Indication LED(UP LED)

After passing setup time. LED is ON at the same time when operating time-limit output.

 

Power Supply Indication LED(ON LED)

LED is OFF when timer works. LED is ON at the same time when operating time-limit output and its status will be maintained.

 

Time Display

It's possible to change time setup together with knob and you can change setup time in the middle of it's function.

 

Time unit setup switch (s/m/h)

It is consisted of Hour(h), Minute(m),Second(s). You can set and use time unit what you need.(Available to change it when Power is OFF)

 

 

TF62N

 

Flicker-ON output indication LED

In case of Flicker-ON, LED is ON at the same time when operating time-limit output.

 

Flicker-OFF output indication LED

in case of Flicker-ON, LED is ON at the same time when stopping time-limit output.

 

Flicker-ON time display

It is used to set operating time of time-limit output in the Flicker-ON mode. Setup time could be changed during operation of timer.

 

Flicker-ON time unit setup switch

It is consisted of Hour(h), Minute(m), Second(s). You can set and use ON time unit what you need.(Available to change it when Power is OFF)

 

Flicker-OFF time display

It is used to set stopping time of time-limit output in the Flicker-ON mode. Setup time could be changed during operation of timer.

 

Flicker-OFF time unit setup switch

It is consisted of Hour(h), Minute(m), Second(s). User can set his own Flicker-OFF time unit (Available to change it when Power is OFF)

 

 

TF62D

 

LED for indicating output of Dual-B ON

In case of Dual function, LED is ON at the same time when operating B output.

 

LED for indicating output of Dual-A ON

In case of Dual function, LED is ON at the same time when operating A output.

 

LED for indication output of Dual A/B OFF

In case of Dual function, LED is OFF at the same time when stopping A output or B output.

 

Setup time dispaly of Dual A/B ON

It is used together with knob to set ON operation time setup of A output and B output. Setup time could be changed during operation of timer.

 

Time unit setup switch of Dual A/B ON

It is consisted of Hour(h), Minute(m), Second(s). It is used to set ON time unit of A output and B output. (Available to change it when Power is OFF)

 

Setup time dispaly of Dual A/B OFF

It is used to set OFF operation time setup of A output and B output. Setup time could be changed during operation of timer.

 

Time unit setup switch of Dual A/B OFF

It is consisted of Hour(h), Minute(m), Second(s). It is used to set OFF time unit of A output and B output. (Available to change it when Power is OFF)

 